Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters

Database
Language
Document Type
Year range
1.
J Chromatogr B Analyt Technol Biomed Life Sci ; 1206: 123363, 2022 Aug 15.
Article in English | MEDLINE | ID: covidwho-1914562

ABSTRACT

A fully validated, simple, rapid and reproducible liquid chromatography-tandem mass spectrometry method was developed to determine NHC (N-hydroxycytidine), the active metabolite of Molnupiravir (MOL) in human plasma; one of the limited treatment options for SARS-CoV-2 in plasma of healthy volunteers. The internal standard (IS) used was ribavirin. The extraction of analyte and IS from plasma was performed using acetonitrile as a solvent for protein precipitation. Agilent Zorbax Eclipse plus C18, 4.6 × 150 mm, (5 µm) was used for chromatographic separation using a mixture of methanol0.2 % acetic acid (5:95, v/v) as a mobile phase that was pumped at a flow rate of 0.9 mL/min. Detection was performed on a triple quadrupole mass spectrometer operating in multiple reaction monitoring (MRM) employing positive ESI interface using API4500 triple quadrupole tandem mass spectrometer system, with the transitions set at m/z 260.10 â†’ 128.10 and 245.10 â†’ 113.20 for NHC and IS respectively. Method validation was performed in accordance with United States FDA bioanalytical guidance. The concentration range of 20.0-10000.0 ng/mL was used to establish linearity via weighted linear regression approach (1/x2). Moreover, the analyzed pharmacokinetic data from twelve Egyptian healthy volunteers were used to develop a population pharmacokinetic model for NHC. The developed model was used to perform simulations and evaluate the current MOL dosing recommendations through calculating the maximum concentration (Cmax) "the safety metric" and area under the curve (AUC0-12 h) "the efficacy metric" for 1000 virtual subjects. Geometric mean ratios (GMR) with their associated 90% confidence intervals (CI) compared to literature values were computed. Geometric means of simulation-based Cmax and AUC0-12 were 3827 ng/mL (GMR = 1.05; 90% CI = 0.96-1.15) and 9320 ng.h/mL (GMR = 1.04; 90% CI = 0.97-1.11), respectively indicating that current MOL dosage can achieve the therapeutic targets and dose adjustment may not be required for the Egyptian population. The developed model could be used in the future to refine MOL dosage once further therapeutic targets are identified.


Subject(s)
Antiviral Agents , COVID-19 , Prodrugs , Tandem Mass Spectrometry , Antiviral Agents/blood , Chromatography, Liquid/methods , Cytidine/analogs & derivatives , Egypt , Healthy Volunteers , Humans , Hydroxylamines/blood , Reproducibility of Results , SARS-CoV-2 , Tandem Mass Spectrometry/methods
2.
J Pharm Biomed Anal ; 199: 114057, 2021 May 30.
Article in English | MEDLINE | ID: covidwho-1164115

ABSTRACT

A novel, fast and sensitive LC-MS/MS method was developed and validated for the bioanalysis of the antiviral agent favipiravir (FAV); a promising candidate for treatment of SARS-CoV-2 (COVID-19) in human plasma using pyrazinamide as an internal standard (IS). Simple protein precipitation was adopted for plasma sample preparation using methanol. Chromatographic separation was accomplished on Eclipse plus C18 column (50 × 4.6 mm, 3.5 µm) using a mobile phase composed of methanol-0.2 % acetic acid (20:80, v/v) pumped at a flow rate 0.6 mL/min in an isocratic elution mode. The API4500 triple quadrupole tandem mass spectrometer was operated with multiple-reaction monitoring (MRM) in negative electrospray ionization interface for FAV and positive for IS. The MRM function was used for quantification, with the transitions set at m/z 156.00→ 113.00 and m/z 124.80→ 81.00 for FAV and IS. The method was optimized and fully validated in accordance to US-FDA guidelines. Linearity was acquired over a concentration range of 100.0-20000.0 ng/mL by computing using weighted linear regression strategy (1/x2). The proposed method was effectively applied for the pharmacokinetic evaluation of FAV and to demonstrate the bioequivalence of a new FAV formulation (test) and reference product in healthy Egyptian human volunteers.


Subject(s)
COVID-19 , SARS-CoV-2 , Amides , Antiviral Agents , Chromatography, Liquid , Egypt , Emergency Treatment , Healthy Volunteers , Humans , Pyrazines , Reproducibility of Results , Tandem Mass Spectrometry , Therapeutic Equivalency
SELECTION OF CITATIONS
SEARCH DETAIL